Back to search
SAM.govRef NIH-NOI-27-PCA-NIAID-12762

A follow-on service contract for the CytoFlex SRT flow cytometer

NNATIONAL INSTITUTES OF HEALTH logo
Contracting officeNational Institutes of Health
PlanningSuppliesNAICS 811210
Submission deadlineDec 7, 202611:00 AM EST1 week left
PublishedNov 25, 2026
LocationBethesda, MD
Notice type
Special Notice
Product or service code
6640 · LABORATORY EQUIPMENT AND SUPPLIES
Set-aside
Not specified
Place of performance
MarylandBethesda, MD
Official notice
View on SAM.gov ↗

Description

NOTICE OF INTENT TO AWARD A SOLE SOURCE CONTRACT Notice Number: NIH-NOI-27-PCA-NIAID-12762 Posted Date: November 25, 2026 Response Due Date: December 7, 2026 Classification Code: 6640 – Laboratory Equipment and Supplies NAICS Code: 811210 – Electronic and Precision Equipment Repair and Maintenance 1. Agency and Contracting Activity Department of Health and Human Services (HHS) National Institutes of Health (NIH) National Institute of Allergy and Infectious Diseases (NIAID) Division of Intramural Research (DIR) Laboratory of Viral Diseases (LVD) For: National Institutes of Health NIAID/LVD Building 33, Room 1E05 33 North Drive Bethesda, MD 20892 Project Number: PCA-NIAID-12762 Project Title: Service Contract for CytoFLEX SRT 2. Action Being Announced This is a notice of intent, and not a request for competitive quotations, proposals, or bids. The National Institutes of Health (NIH), on behalf of the National Institute of Allergy and Infectious Diseases (NIAID), intends to negotiate and award a firm-fixed-price sole source contract to: Beckman Coulter, Inc. 5350 Lakeview Parkway South Drive Indianapolis, IN 46268 for a one-year service contract to provide preventive maintenance, repair coverage, OEM parts, labor, travel, priority response, phone support, engineering modifications, and operator training for the CytoFLEX SRT, serial number BF32140. 3. Statutory Authority The Government intends to award this requirement on a sole source basis pursuant to: 41 U.S.C. 3304(a)(1) and FAR 13.106-1(b)(1), soliciting from a single source for purchases at or below the simplified acquisition threshold, as applicable; Under simplified acquisition procedures, contracting officers may solicit from one source when circumstances deem only one source reasonably available This sole source determination is based on the conclusion that only one source is capable of providing the services required at the level of quality required because the services are unique and highly specialized. 4. Description of Requirement The National Institute of Allergy and Infectious Diseases (NIAID), Division of Intramural Research (DIR), Laboratory of Viral Diseases (LVD), requires a one-year service contract for the CytoFLEX SRT, serial number BF32140. The required service coverage includes, at a minimum: One (1) preventive maintenance inspection during the period of performance by a Beckman Coulter-authorized and factory-certified technician; Coverage for repair, OEM parts, labor, and travel; Priority response and telephone support; Engineering modifications supported by genuine new parts; and Additional key operator training during regular service visits. The anticipated period of performance is January 1, 2027 through December 31, 2027. The total estimated value of the requirement is $43,635.00. 5. Background Research programs in the Laboratory of Viral Diseases (LVD) explore fundamental aspects of cell and molecular biology, viral pathogenesis, and viral immunology within the context of a diverse group of medically important viruses, including human/simian immunodeficiency viruses, poxviruses, herpesviruses, papillomaviruses, coronaviruses, influenza viruses, alphaviruses, and flaviviruses. The goals of these research programs are to increase basic biological understanding of these pathogens and their interactions with their hosts and to generate new strategies for preventing and treating viral diseases. This equipment is used by the Single Virion Biology & Biophysics Unit in the Laboratory of Viral Diseases. The research program broadly focuses on uncovering fundamental molecular mechanisms of virus translocation across cell membranes. The CytoFLEX SRT flow cytometer and cell sorter is essential to pursuing the research objectives of the Ivanovic laboratory. The CytoFLEX SRT is used to detect and measure traits and sort cell and virion populations from research projects investigating the morphology of influenza virions and other aspects of influenza biology. The instrument is located on the NIH main campus in Building 33, Room 1E19, Bethesda, Maryland. 6. Sole Source Determination In accordance with FAR Part 10 and applicable HHS acquisition guidance, market research was conducted for this requirement. Market research included: application of personal knowledge in procuring similar services; contacting knowledgeable individuals in Government and industry regarding market capabilities; participation in online communication among industry, acquisition personnel, and customers; obtaining source lists from other contracting activities, agencies, trade associations, and other sources; and reviewing catalogs and generally available product literature published by manufacturers, distributors, and dealers or available online. The Scientific Operations Manager reviewed required sources, Federal Supply Schedules, NIH strategic sourcing resources, and commercial websites and determined that only Beckman Coulter offers the required level of OEM service support for the CytoFLEX SRT. Specifically, Beckman Coulter was the only source identified that can provide: unlimited guaranteed OEM replacement service parts, components, or modules necessary for repairs; priority response on-site service; unlimited telephone support; compatible software revisions; engineering modifications supported by genuine new parts; and additional key operator training throughout the agreement term. The CytoFLEX SRT is specialized for the detection of small virus particles and sorting of infectious populations, unlike other flow cytometers that function primarily at the larger cellular level. The instrument includes specialized lasers and resolution capabilities necessary to detect and sort individual virions as required by the research projects in the Single Virion Biology & Biophysics Unit. Only Beckman Coulter provides the necessary specialized supplies and manufacturer-authorized service support for the CytoFLEX SRT, and only Beckman Coulter-trained technicians possess the expertise required to maintain the instrument in proper working order while preserving manufacturer support. Accordingly, no other source is known that can satisfy the Government’s requirement without unacceptable risk to instrument performance, research continuity, and data integrity. 7. Procurement History This requirement is for continued service support of the CytoFLEX SRT.

Procurement History: The instrument transferred to LVD in 2021 and has been covered by service contracts since that time.

Previous Purchase Orders: LAW2135976, 75N93023P00156, and associated option years Current AMBIS Sequence Number: 2309556 8. Responses from Interested Sources This notice is not a solicitation. However, any responsible source that believes it is capable of meeting the Government’s requirement may submit a capability statement for consideration. Interested parties must demonstrate, through clear and convincing documentation, their ability to provide service support equivalent to that described in this notice for the CytoFLEX SRT, serial number BF32140. Capability statements shall include, at a minimum: company name and address; description of the vendor’s authorization to service the CytoFLEX SRT; evidence of access to OEM parts, components, software revisions, and engineering modifications; documentation demonstrating ability to provide priority response on-site service; description of technician qualifications and factory certification specific to the CytoFLEX SRT platform; and explanation of how the vendor will meet each of the Government’s minimum requirements. Responses must be received no later than December 7, 2026. Responses shall be submitted electronically to: Primary Contact: Linda Smith [email protected] Secondary Contact: Danielle Tines [email protected] The subject line shall reference: Notice Number NIH-NOI-27-PCA-NIAID-12762 9. Government Notice This notice is provided for informational purposes only and does not constitute a request for proposals, quotations, or bids. The Government does not intend to pay for any information submitted in response to this notice. All responses received by the closing date will be reviewed by the Government solely for the purpose of determining whether competitive sources exist. A determination by the Government not to compete this proposed action, based upon responses to this notice, is solely within the discretion of the Government.

The rest of this notice

The buyer's named contact and the award details for this notice are free. Create an account to open the full record.

  • Contact the buyer directly
  • See who won, and for how much
  • Get alerts for opportunities like this one
Create a free account

Free — no card, no trial clock.

Get new Electronic and Precision Equipment Repair and Maintenance contracts by email — free, no card needed.
Create a free alert