Hydrogen Generator for Gas Chromatography

SSTATE, DEPARTMENT OF logo
Contracting officeDepartment of State
ActiveSuppliesNAICS 334516
Closes in 1 day. Submissions due Friday, November 13, 2026 at 10:00 AM EST.
Submission deadlineNov 13, 202610:00 AM EST1 day left
PublishedOct 28, 2026
LocationKingston, JM-02
Notice type
Combined Synopsis/Solicitation
Product or service code
6640 · LABORATORY EQUIPMENT AND SUPPLIES
Set-aside
Not specified
Place of performance
Kingston, JM-02
Official notice
View on SAM.gov ↗

Description

The United States Embassy seeks qualified and authorized reseller of one (1) on demand laboratory hydrogen generator, plus installation, gas distribution, commissioning, training and warranty services, as described below: PEAK SCIENTIFIC INTURA H2 250 HYDROGEN GENERATOR (AUTO-FILL), WITH MANUFACTURER'S STANDARD WARRANTY QUANTITY: 1 Peak Scientific part number: 3305698-0-02 (auto-fill) Flow rate up to 250 cc/min; 99.99999% purity; output pressure up to 175 psi Standard warranty: 12-month comprehensive warranty and 36-month PEM cell warranty both starting at Government acceptance Operator's manual and warranty certificate in English PEAK INTURA H2 ANNUAL SERVICE KIT QUANTITY: 1 Peak Scientific part number: 3306178 ON-SITE INSTALLATION, GAS DISTRIBUTION, COMMISSIONING AND TRAINING QUANTITY: 1 Firm-fixed price. No extra labor-hour charges. Performed at IFSLM, Kingston, Jamaica, by Peak-certified technicians, in English. Supply and install all clean, GC-grade tubing, fittings, tees/manifolds and point-of-use regulators to deliver hydrogen to the Agilent 7890A GC/5975C VL MSD and the Agilent 7890A GC-FID, which sit next to each other. Connect the generator to the lab's existing DI water supply for auto-fill. Leak-test every connection. Show that each instrument works on generator-supplied hydrogen, including the switch from helium to hydrogen carrier gas on the 5975C system. Provide one (1) day of on-site operator training for approximately ten (10) IFSLM staff, covering operation, routine maintenance, water quality requirements and hydrogen safety, including safe hydrogen use in the GC oven and MSD. Provide an installation and commissioning report. 004 – SHIPPING TO KINGSTON, JAMAICA QUANTITY: 1 FOB Destination: U.S. Embassy Kingston, 142 Old Hope Road Kingston 6 Jamaica, including all customs, brokerage, insurance and freight charges for the items to be delivered door to door (DTP). Contractor bears risk of loss until Government acceptance at the embassy.

The rest of this notice

The buyer's named contact and the award details for this notice are free. Create an account to open the full record.

  • Contact the buyer directly
  • See who won, and for how much
  • Get alerts for opportunities like this one
Create a free account

Free — no card, no trial clock.

Get new Analytical Laboratory Instrument Manufacturing contracts by email — free, no card needed.
Create a free alert